Surface Cleanliness Standards
Knowledge Base5 entries
Frequently Asked Questions
SP6 Commercial Blast — 2/3 of every sq inch free of all visible contaminants. Light staining and shadows allowed.
SP10 Near-White Blast — 95% of every sq inch free of all visible contaminants. Only random light staining allowed.
Flash rust is the thin orange film that forms on freshly blasted steel within minutes of exposure to humid air or water. Three grades per ISO 8501-3:
- Grade L (light) — usually acceptable for most coatings
- Grade M (medium) — brush off; acceptable for some forgiving coatings
- Grade H (heavy) — reblast required
Always start with the coating data sheet. Common ranges:
| Coating Class | Typical Profile |
|---|---|
| Zinc-rich primer (inorganic) | 1.5–2.5 mil |
| Epoxy primer | 3–5 mil |
| High-build epoxy / urethane | 3–6 mil |
| Tank lining / immersion | 4–6 mil |
Table 1 — Profile by coating class.
SSPC (Society for Protective Coatings) merged with NACE in 2021 to form AMPP (Association for Materials Protection and Performance). The technical standards (SP1–SP15, PA1–PA17, QP1–QP8) are unchanged — only the issuing body's name changed. Specs may reference either SSPC, NACE, or AMPP; they're interchangeable for the underlying standards.
Sweep blast (SSPC-SP7 "brush-off") is the lightest blast cleaning — loose rust, scale, and previous coating removed but tight adherent coating left in place. Used to roughen an existing intact coating for recoat after the recoat window has expired, not for new-construction prep.